Re: [net-next,PATCH v2] enetc: Increase eMDIO MDC rate to 2.5 MHz
From: Marek Vasut
Date: Thu Oct 01 2026 - 18:01:09 EST
On 9/30/26 3:27 PM, Marek Vasut wrote:
Hello again,
Clark helped measure the MDC rate on the 95 EVK board this morning, and the
result was 644KHz, which is consistent with the theoretical value. The scope's
accuracy or other factors may be causing you to observe a rate of 558kHz.
That 644 kHz and 558 kHz differs too much to be an equipment miscalibration / misuse.
For the sake of completeness, the MX95 B0 I have on my desk now prints this in SM:
>$ clock.r
...
097: busnetcmix = on, 133333333Hz
098: enet = on, 666666666Hz
099: enetphytest200m = on, 24000000Hz
100: enetphytest500m = on, 24000000Hz
101: enetphytest667m = on, 24000000Hz
102: enetref = on, 250000000Hz
103: enettimer1 = on, 24000000Hz
And the cycle time of MDC is 1.8ms , which is some 550 kHz .