Re: [PATCH] power: supply: qcom_battmgr: do not report power_now on SM8750
From: Qianhui Xu
Date: Fri Oct 23 2026 - 09:54:28 EST
Hi Konrad,
> Did you try reaching out to the vendor?
No, and I want to be precise about why rather than hand-wave it:
- This tablet (Lenovo Legion Y700 Gen4, TB322FC) has no vendor channel for
kernel sources. The public support surface is consumer warranty, not
engineering. We are an independent bring-up, not a customer of theirs.
- I also asked the person who is upstreaming the mainline DT for this same
board (separate thread, private) whether a downstream tree exists publicly.
There are partial downstream trees for sibling Lenovo tablets, but none that
covers this unit's QBG/battery path.
So "ask the vendor" is not available to us. What I could do instead, I did:
boot the unit's own stock Android and compare it against mainline on the same
battery.
STOCK ANDROID SIDE (slot a, same unit)
build: Lenovo/TB322FC_PRC/TB322FC:16/BQ2A.250610.001-BP2A.250605.031.A3/\
ZUXOS_1.5.10.259_260611_PRC:user/release-keys
dumpsys battery: level 94%, voltage 4309 mV, charge_counter 6439000 uAh,
temperature 32.3 C, status 2 (charging), health 2
Limits I hit, stated plainly: this is a user/release-keys build, so no adb
root, and SELinux denies the shell domain access to
/sys/class/power_supply/battery. I could not read the downstream kernel's own
power_now attribute. Two things I could check from userspace:
- the Android battery stack never surfaces power_now at all: it is not in
dumpsys battery, and a full logcat scan for power_now / BATT_POWER returns
zero hits.
- therefore "is power_now disabled downstream too" has no answer from a user
build - the platform has no validated consumer of that property.
MAINLINE SIDE (same unit, same battery, same QBG firmware, minutes later)
charge_counter 6489760 uAh, voltage_now 4285000 uV, current_now -1003000 uA,
temp 32.1 C, capacity 94%
The shared QBG values agree with the stock numbers (charge counter within 0.8%,
voltage 24 mV, temperature 0.2 C). So the property plumbing is not the problem:
the only quantity that disagrees is POWER_NOW, and the stock stack does not use
it.
WHAT WE DO IN OUR TREE
Our SM8750 battmgr description simply does not advertise the property (the
sm8550 property list minus the trailing POWER_NOW), so on our dailies
/sys/class/power_supply/qcom-battmgr-bat has no power_now file at all - that is
what the patch you already have does.
If a readback of the raw downstream slot would settle it for you, I can unlock
and root this unit and read the value directly - it costs us a slot switch and
an unlock, so tell me if it is actually load-bearing for the patch, otherwise I
would rather keep the unit usable.
Thanks,