Re: [PATCH 6/7] dt-bindings: serial: max310x: Add maxim,tristate-when-closed
From: Tapio Reijonen
Date: Tue Nov 24 2026 - 02:08:14 EST
On 23/11/2026 09:05, Krzysztof Kozlowski wrote:
>> + Three-state the channel's TX and RTS outputs whenever the port is
>> + not open, from probe until the first open and after each close.
>
> Property name and description should reflect hardware characteristic,
> not what OS should do.
Understood. The hardware fact is that the channel's TX and RTS outputs
go to a part that can be unpowered, or to a line that another device
can drive, so the UART must not drive them while the channel is unused.
Would this be acceptable:
maxim,outputs-high-impedance-when-unused:
$ref: /schemas/types.yaml#/definitions/flag
description:
The TX and RTS outputs of this channel are connected to a part
that can be unpowered, or to a line that another device can
drive. The outputs have to be high impedance whenever the
channel is not in use.
Best regards,
Tapio