RE: [PATCH 1/2] dt-bindings: iio: adc: adi,ad7124: make interrupts optional

From: Ilyas NHASSE

Date: Tue Nov 24 2026 - 03:49:24 EST


On Fri, Nov 20, 2026 at 05:46:10PM +0000, Conor Dooley wrote:
> On Fri, Nov 20, 2026 at 12:26:47PM +0100, ILYAS NHASSE via B4 Relay wrote:
>> The AD7124 signals the end of a conversion on its DOUT/RDY pin, which is
>> also the SPI MISO line. Using it as an interrupt requires the board to
>> route that pin to an interrupt-capable input as well, which is not always
>> possible, e.g. when the ADC sits behind a digital isolator that only
>> carries the SPI signals.
>
> What does this actually mean? Does the isolator only permit data
> transmission when CS is active?

No, the isolator passes the SPI signals normally. On our board DOUT/RDY
crosses it as MISO and then only goes to the SPI controller's MISO
input; it isn't also routed to a GPIO or other interrupt-capable input.
The isolator doesn't really matter, so as Jonathan suggested, v2 will
only say that DOUT/RDY may not be wired to an interrupt.

Thanks,
Ilyas