RE: [PATCH rtw-next v14 3/3] wifi: rtw88: time the countdown downloads from the TBTT
From: Luka Gejak
Date: Tue Nov 24 2026 - 04:52:47 EST
On November 24, 2026 10:09:56 AM GMT+01:00, Ping-Ke Shih
<pkshih@xxxxxxxxxxx> wrote:
>Hi Mehmet,
>
>Mehmet Fide <mehmet.fide@xxxxxxxxx> wrote:
>> Hi Luka,
>>
>> > Could the wait for the safe part of the interval use a finer timer, or
>> > could we limit CSA to intervals the timer can reliably handle?
>>
>> Agreed for short intervals with HZ=100. A finer timer would not help
>> much on USB, where the download itself takes 6 to 17 ms. At 100 TU no
>> count repeats (model with HZ=100, rig with HZ=250). If Ping-Ke wants, a
>> minimum interval check can be a separate patch.
>
>In my opinion, we can just fix the real case you encountered, and yes
>we can think about the different HZ cases in detail. However, we don't
>need to consider too many corner cases, which spend a lot of time,
>but actually never happen. Sometime in the future, if it happens,
>we can spin another patch to fix it. No need a perfect patch.
>
Makes sense, I will take that into account for future.
Best regards,
Luka Gejak