Re: [PATCH v4 8/8] dt-bindings: stm32: use reference manual names for ETR and STM bus clocks
From: Krzysztof Kozlowski
Date: Tue Nov 24 2026 - 10:01:25 EST
> The bus clocks of the STM and of the ETR are identified by CK_BUS_STM500,
> CK_SCMI_STM500 and CK_SCMI_ETR. Now that their kernel clocks are
> described as CK_KER_STM and CK_KER_ETR, and as the RCC bus clock of the
> ETR is already CK_BUS_ETR, these names are confusing. They also differ
> from the reference manual and from the STM32MP21 binding, which uses
> CK_BUS_STM, CK_SCMI_BUS_ETR and CK_SCMI_BUS_STM for the same clocks.
>
> Use CK_BUS_STM, CK_SCMI_BUS_ETR and CK_SCMI_BUS_STM, with unchanged
> values, and keep the old names as deprecated aliases so that the
> existing users are not affected.
>
> No functional change.
That's ABI break, so clearly not true. Users of this ABI - this header -
did compile before, now they don't.
ABI impact must be explicit in commit msg.
Best regards,
Krzysztof
--
Krzysztof Kozlowski <krzk@xxxxxxxxxx>