I have trouble accessing a CD-ROM via my SCSI Plextor CD, connected
to a Tekram DC390 (AM53C974 driver).
When I try to mount it, I get this error:
mount: wrong fs type, bad option, bad superblock on /dev/scd0,
or too many mounted file systems
and in the logs:
VFS: Disk change detected on device sr(11,0)
attempt to access beyond end of device
0b:00: rw=0, want=688290, limit=203728
isofs_read_super: bread failed, dev=0b:00, iso_blknum=344144, block=344144
When I do the SAME mount on my IDE CD, same machine, it works, and the logs
say:
VFS: Disk change detected on device ide0(3,64)
scanning for RockRidge behind XA attribute
last message repeated 38 times
and I can then access the CD-ROM.
This is a picture CD-ROM burned by a shop in France (FNAC, in case there
are other french readers).
With VMWare running on the same machine, when I connect the IDE CD-ROM to
the virtual machine, I can read the CD, but partially. Some directories
are missing. So the CD-ROM is not "clean" -- I suspect the session is not
closed.
What troubles me is the different behaviour between the SCSI CD-ROM and the
IDE one. Any explaination?
Raphael
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/
This archive was generated by hypermail 2b29 : Mon Apr 23 2001 - 21:00:27 EST