Hi Steve,
I have the same problem here (3c575 too, K6-2 too). Cardbus bridge TI1251B.
But I noticed that it nearly never occurs when I put my notebook in a cold
room. Also, it occurs more often when I have transmitted lots of data and the
notebook is hot. In my case, I believe it comes from the cardbus bridge not
coping with the card speed. Perhaps under windows the card is underloaded and
the bridge can keep cool ? but I definitely think it's a hardware problem first
and perhaps the software can mask it.
If you want to reduce the penalty of these timeouts, you can put this line
in your /etc/modules.conf : "options 3c59x watchdog=50". It prevents the
card from hanging more than 50 ms. But take care of your syslog !
Regards,
Willy
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html