"Richard B. Johnson" wrote:
>
> Weird. I have two identical SCSI drives. They both synchronize
> at 40 Mb/s on my Buslogic controller. They are the two ...
> Vendor: SEAGATE Model: ST318233LWV Rev: 0002
> ... drives shown below.
>
> They both have ext2 file-systems occupying a single partition.
> The time to write a file that fills up the file-system on the
> "Id: 01" drive is about 1/2 an hour and the time to write a
> file that fills up the file-system on "Id: 02" is about 1/2 day!
>
> This is with the file created with "O_SYNC". If the file is
> not created with "O_SYNC", there is no apparent difference in
> write speed.
>
> If I swap the jumpers on the two drives to isolate the drives
> from the problem, the slooooo drive is the logical "ID: 02",
> always... not the physical one!
>
O_SYNC writes takes different time depending on the scsi ID?
_Very_ strange, unless your /etc/fstab looks different for
/dev/sdbX and /dev/sdcX
I.e. different mount options that indeed depend on scsi id.
Also check to make sure nothing else is running and accessing
any partition on sdc, that might force those sync writes
to seek more. (I guess the slow disk is noisy?)
Helge Hafting
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/
This archive was generated by hypermail 2b29 : Fri Feb 15 2002 - 21:01:06 EST