Re: [PATCH] SIIG 8-port serial boards support
From: Russell King
Date: Fri Feb 17 2006 - 16:37:09 EST
On Fri, Feb 17, 2006 at 03:27:44PM -0600, Paul Fulghum wrote:
> Russell King wrote:
> >So, there are three distinct flow control scenarios:
>
> So I'm clear on how you interpret these,
> am I correct with the following?
>
> >- conventional RTS/CTS
> RTS active = ready to receive
> CTS active = allowed to send
>
> >- alternative RTS/CTS
> RTS active = on before send, off after send
> CTS active = allowed to send
I'll have to dig through my archives to confirm this one.
> >- RS485
> RTS active = on before send, off after send (RTS enables driver)
> CTS ignored (2 wire mode, no CTS)
>
> So maybe the extra control fields would be:
> CRTSONTX - RTS on before send, off after send
> CTXONCTS - wait for CTS before sending
That's a possibility, except that programs today expect CRTSCTS to
enable RTS/CTS flow control.
What I suggest is to use CRTSCTS to enable the chosen flow control
method. Then we have a set of cflag bits which describe the flow
control mode, eg CFLOWRS485, CFLOWMODEM, CFLOWALT (probably needs
better names.) CFLOWMODEM being the conventional mode should have
an all zeros value.
--
Russell King