[PATCH] Altix snsc: duplicate kobject fix

From: Greg Howard
Date: Fri Apr 21 2006 - 11:50:54 EST


from: Greg Howard <ghoward@xxxxxxx>

This patch fixes Altix system controller (snsc) device names to
include the slot number of the blade whose associated system
controller is the target of the device interface. Including the
slot number avoids a problem we're currently having where slots
within the same enclosure are attempting to create multiple
kobjects with identical names.

The patch should apply cleanly to 2.6.17.

Signed-off-by: Greg Howard <ghoward@xxxxxxx>
---
--- a/linux/drivers/char/snsc.c 2006-04-21 10:19:06 -05:00
+++ b/linux/drivers/char/snsc.c 2006-04-20 14:55:20 -05:00
@@ -390,7 +390,8 @@ scdrv_init(void)
format_module_id(devnamep, geo_module(geoid),
MODULE_FORMAT_BRIEF);
devnamep = devname + strlen(devname);
- sprintf(devnamep, "#%d", geo_slab(geoid));
+ sprintf(devnamep, "^%d#%d", geo_slot(geoid),
+ geo_slab(geoid));

/* allocate sysctl device data */
scd = kzalloc(sizeof (struct sysctl_data_s),
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in