Re: e1000/ICH8LAN weirdness - no ethtool link until initially forced up

From: Robin H. Johnson
Date: Tue Nov 07 2006 - 16:51:52 EST


On Tue, Nov 07, 2006 at 07:51:22AM -0800, Auke Kok wrote:
> >I think you should cc e1000 maintainers, and perhaps provide a patch....
> I've read it and not come up with an answer due to some other issues at
> hand. E1000 hardware works differently and this has been asked before, but
> the cards itself are in low power state when down. Changing this to bring
> up the link would make the card start to consume lots more power, which
> would automatically suck enormously for anyone using a laptop.
>
> Unfortunately, we have no way to distinguish directly between mobile and
> non-mobile adapters, since they are usually the same.
>
> Your application should really `ifconfig up` the device before checking for
> link.
Actually pushing the link up in userspace doesn't specifically help my
applications, as I care about actual link status (as reported by
ethtool).

Is there no way to keep the link status correct (within 0.5 seconds),
without bringing the card to full power? Maybe a timer that fires a
proper check (with the power implications).

Would a patch that adds a modparam (not enabled by default) running the
behavior I'm after, be acceptable, so the e1000 driver can act identical
to all of the other drivers?

--
Robin Hugh Johnson
E-Mail : robbat2@xxxxxxxxxx
GnuPG FP : 11AC BA4F 4778 E3F6 E4ED F38E B27B 944E 3488 4E85

Attachment: pgp00000.pgp