hpa-problem in ide-disk.c - new insights.
From: Andreas Leitgeb
Date: Mon Nov 27 2006 - 08:10:53 EST
It appears, as if the drive is really approaching breakdown,
remapping bad sectors and is out of spare sectors. Thus
reducing capacity. The call to determine the native
sectors seems to still count in those remapped sectors,
yielding an effectively bogus number.
Perhaps the drive had originally 78165361 sectors, and
(speculating further) the problems only started to show
up, when the "current" sectors dropped down to 78165360,
while the "native" sectors remained at 78165361.
Since I've got no precious data on that disk (anymore),
I'll just watch it, until it suffers the final headcrash.
PS:
It would still be good to be able to turn off hpa-checking
with some module/boot-option to help with any drives that
return effectively wrong "native" capacity (whether they're
actually broken, or might just have a broken firmware).
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/