On Wed, 8 Aug 2007, Oncaphillis wrote:
Greetings,
I'm trying to compile a 2.6.2x kernel on a Linkstation/KuroBox HG/ppc
following instructions given under
http://www.kurobox.com/mwiki/index.php/Kurobox_support_in_stock_2.6_kernels
Wow, congratulations! Not too many endevour into this land, and even fewer succeed:-) You'd probably be better off asking this on linuxppc-dev, but anyway...
and get weired settings and errors from the serial device (UART 16550A).
Under the 2.4.17 kernel provided by the Kurobox manufacturer it gets IRQS in
the range of 137/138 under 2.6.22 for the linkstation it gets IRQS 17/18 and
the serial device behaves fishy
That interrupt numbers are different as under 2.4 is correct, however, I get 16 and 17 for ttyS0 and ttyS1 on a kuroboxHG, are you sure you're getting 17 and 18?
communication errors
"to much work in IRQ 16"
And here you get IRQ 16, which indeed should be ttyS0. And ttyS0 is connected to the power-management microcontroller (AVR). Wait, what userspace are you running? Have you swapped ttyS0 and ttyS1 everywhere? in /etc/inittab for example? Besides, if you are running any vendor provided (or community) tools to handle the AVR - they use ttyS1 by default, as it was under 2.4 ans under "traditional" 2.6, whereas the 2.6 mainline kernel for kurobox/linkstation uses the traditional for these CPUs port numbering. I think this is your problem. Some user-space programme(s) are accessing wrong tty.
Thanks
Guennadi
---
Guennadi Liakhovetski
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/