The ds18b20 one wire temperature sensor conversion routine is
returning the units in degrees C while the ds1820 (ds18s20) is
returning it in .001 degrees C. 20C vs 20312C. Once you know the
units I'm liking the latter as it gives a higher precision. Time to
break user applications so the driver can give the temperature in the
same units for both sensors.
I only have the ds18b20 sensor model. Here is the current output from
the sys file for this sensor.
/sys/devices/w1_bus_master1/28-0000000e84a2/w1_slave
45 01 4b 46 7f ff 0b 10 84 : crc=84 YES
45 01 4b 46 7f ff 0b 10 84 t=20
I ran the example data from the specification for the ds1820 through
it's conversion routine and found that t= was 1000 times the value. What should the displayed units be?
This is the same ds18b20 conversion *1000. Is everyone ok or is any
objecting to .001 degrees C for the units? Patch will follow. The
.001 C does truncate one bit of precision from the ds18b20 by the way.