Re: NIU - Sun Neptune 10g - Transmit timed out reset (2.6.24)
From: Bill Fink
Date: Fri May 09 2008 - 22:20:59 EST
On Sat, 10 May 2008, Jesper Krogh wrote:
> Rick Jones wrote:
> >
> > Into which slot was the Neptune inserted? (sure will be nice to have
> > Alex Chiang's pci slot id patch in mainline one of these days :)
> >
> > Is that slot x4, x8, x16?
>
> I can find out excactly .. on monday. But shouldn't x4 be enough anyway?
> wikipedia says 250MB/s pr. lane. And no slots is less than x4, so I
> thought that it didn't matter to me.
No you need 8x for 10-GigE. The 250 MB/sec per lane is 2 Gbps per lane
so 4x is only 8 Gbps. For a typical PCI-E transaction size of 128 bytes,
and PCI-E protocol overhead of 20 to 24 bytes, that takes off about 20%,
which leaves you with about 6.5 Gbps of usable bandwidth, which is further
reduced somewhat by the required PCI-E ACK and flow control packets that
accompany the actual data transaction packets. I am not an expert on
PCI-E but I believe this info to be generally correct.
-Bill
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/