[PATCH 2/5] firewire: fw-sbp2: fix spindown for PL-3507 and TSB42AA9firmwares

From: Stefan Richter
Date: Sat May 10 2008 - 18:35:29 EST


Reported by Tino Keitel: PL-3507 with firmware from Prolific does not
spin down the disk on START STOP UNIT with power condition = 0 and start
= 0. It does however work with power condition = 2 or 3.

Also found while investigating this: DViCO Momobay CX-1 and FX-3A (TI
TSB42AA9/A based) become unresponsive after START STOP UNIT with power
condition = 0 and start = 0. They stay responsive if power condition is
set when stopping the motor.

Signed-off-by: Stefan Richter <stefanr@xxxxxxxxxxxxxxxxx>
---
drivers/firewire/fw-sbp2.c | 22 ++++++++++++++++++++--
1 file changed, 20 insertions(+), 2 deletions(-)

Index: linux/drivers/firewire/fw-sbp2.c
===================================================================
--- linux.orig/drivers/firewire/fw-sbp2.c
+++ linux/drivers/firewire/fw-sbp2.c
@@ -86,6 +86,11 @@ MODULE_PARM_DESC(exclusive_login, "Exclu
* - delay inquiry
* Wait extra SBP2_INQUIRY_DELAY seconds after login before SCSI inquiry.
*
+ * - power condition
+ * Set the power condition field in the START STOP UNIT commands sent by
+ * sd_mod on suspend, resume, and shutdown (if manage_start_stop is on).
+ * Some disks need this to spin down or to resume properly.
+ *
* - override internal blacklist
* Instead of adding to the built-in blacklist, use only the workarounds
* specified in the module load parameter.
@@ -97,6 +102,7 @@ MODULE_PARM_DESC(exclusive_login, "Exclu
#define SBP2_WORKAROUND_FIX_CAPACITY 0x8
#define SBP2_WORKAROUND_DELAY_INQUIRY 0x10
#define SBP2_INQUIRY_DELAY 12
+#define SBP2_WORKAROUND_POWER_CONDITION 0x20
#define SBP2_WORKAROUND_OVERRIDE 0x100

static int sbp2_param_workarounds;
@@ -107,6 +113,8 @@ MODULE_PARM_DESC(workarounds, "Work arou
", skip mode page 8 = " __stringify(SBP2_WORKAROUND_MODE_SENSE_8)
", fix capacity = " __stringify(SBP2_WORKAROUND_FIX_CAPACITY)
", delay inquiry = " __stringify(SBP2_WORKAROUND_DELAY_INQUIRY)
+ ", set power condition in start stop unit = "
+ __stringify(SBP2_WORKAROUND_POWER_CONDITION)
", override internal blacklist = " __stringify(SBP2_WORKAROUND_OVERRIDE)
", or a combination)");

@@ -310,18 +318,25 @@ static const struct {
.firmware_revision = 0x002800,
.model = 0x001010,
.workarounds = SBP2_WORKAROUND_INQUIRY_36 |
- SBP2_WORKAROUND_MODE_SENSE_8,
+ SBP2_WORKAROUND_MODE_SENSE_8 |
+ SBP2_WORKAROUND_POWER_CONDITION,
},
/* DViCO Momobay FX-3A with TSB42AA9A bridge */ {
.firmware_revision = 0x002800,
.model = 0x000000,
- .workarounds = SBP2_WORKAROUND_DELAY_INQUIRY,
+ .workarounds = SBP2_WORKAROUND_DELAY_INQUIRY |
+ SBP2_WORKAROUND_POWER_CONDITION,
},
/* Initio bridges, actually only needed for some older ones */ {
.firmware_revision = 0x000200,
.model = ~0,
.workarounds = SBP2_WORKAROUND_INQUIRY_36,
},
+ /* PL-3507 bridge with Prolific firmware */ {
+ .firmware_revision = 0x012800,
+ .model = ~0,
+ .workarounds = SBP2_WORKAROUND_POWER_CONDITION,
+ },
/* Symbios bridge */ {
.firmware_revision = 0xa0b800,
.model = ~0,
@@ -1539,6 +1554,9 @@ static int sbp2_scsi_slave_configure(str
if (lu->tgt->workarounds & SBP2_WORKAROUND_FIX_CAPACITY)
sdev->fix_capacity = 1;

+ if (lu->tgt->workarounds & SBP2_WORKAROUND_POWER_CONDITION)
+ sdev->start_stop_pwr_cond = 1;
+
if (lu->tgt->workarounds & SBP2_WORKAROUND_128K_MAX_TRANS)
blk_queue_max_sectors(sdev->request_queue, 128 * 1024 / 512);


--
Stefan Richter
-=====-==--- -=-= -=-==
http://arcgraph.de/sr/

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/