Re: [RFC patch 08/18] cnt32_to_63 should use smp_rmb()
From: David Howells
Date: Fri Nov 07 2008 - 05:56:31 EST
Mathieu Desnoyers <mathieu.desnoyers@xxxxxxxxxx> wrote:
> Assume the time source is a global clock which insures that time will never
> *ever* go backward. Use a smp_rmb() to make sure the cnt_lo value is read before
> __m_cnt_hi.
If you have an smp_rmb(), then don't you need an smp_wmb()/smp_mb() to match
it to make it work? And is your assumption valid that smp_rmb() will affect
memory vs the I/O access to read the clock? There's no requirement that
cnt_lo will have been read from an MMIO location at all.
David
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html