Re: [patch] ext2/3: document conditions when reliable operation ispossible
From: david
Date: Mon Aug 24 2009 - 19:43:40 EST
On Mon, 24 Aug 2009, Zan Lynx wrote:
Ric Wheeler wrote:
Pavel Machek wrote:
Degraded MD RAID5 does not work by design; whole stripe will be
damaged on powerfail or reset or kernel bug, and ext3 can not cope
with that kind of damage. [I don't see why statistics should be
neccessary for that; the same way we don't need statistics to see that
ext2 needs fsck after powerfail.]
Pavel
What you are describing is a double failure and RAID5 is not double failure
tolerant regardless of the file system type....
Are you sure he isn't talking about how RAID must write all the data chunks
to make a complete stripe and if there is a power-loss, some of the chunks
may be written and some may not?
q write to raid 5 doesn't need to write to all drives, but it does need to
write to two drives (the drive you are modifying and the parity drive)
if you are not degraded and only suceed on one write you will detect the
corruption later when you try to verify the data.
if you are degraded and only suceed on one write, then the entire stripe
gets corrupted.
but this is a double failure (one drive + unclean shutdown)
if you have battery-backed cache you will finish the writes when you
reboot.
if you don't have battery-backed cache (or are using software raid and
crashed in the middle of sending the writes to the drive) you loose, but
unless you disable write buffers and do sync writes (which nobody is going
to do because of the performance problems) you will loose data in an
unclean shutdown anyway.
David Lang
As I read Pavel's point he is saying that the incomplete write can be
detected by the incorrect parity chunk, but degraded RAID-5 has no working
parity chunk so the incomplete write would go undetected.
I know this is a RAID failure mode. However, I actually thought this was a
problem even for a intact RAID-5. AFAIK, RAID-5 does not generally read the
complete stripe and perform verification unless that is requested, because
doing so would hurt performance and lose the entire point of the RAID-5
rotating parity blocks.
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/