On Tue, Aug 25, 2009 at 09:15:00PM -0400, Ric Wheeler wrote:
I agree with the whole write up outside of the above - degraded RAIDThe argument is that if the degraded RAID array is running in this
does meet this requirement unless you have a second (or third, counting
the split write) failure during the rebuild.
state for a long time, and the power fails while the software RAID is
in the middle of writing out a stripe, such that the stripe isn't
completely written out, we could lose all of the data in that stripe.
In other words, a power failure in the middle of writing out a stripe
in a degraded RAID array counts as a second failure.
To me, this isn't a particularly interesting or newsworthy point,
since a competent system administrator who cares about his data and/or
his hardware will (a) have a UPS, and (b) be running with a hot spare
and/or will imediately replace a failed drive in a RAID array.
- Ted