On Thu, 26 Aug 2010, Guenter Roeck wrote:
> > > +temp[1-*]_emergency
> > > + Temperature emergency value, typically greater than
> > > + corresponding temp_crit values.
> > > + Unit: millidegree Celsius
> > > + RW
> > > +
> >
> > If we have two-level alarms: critical, then emergency, it is best to have
> > that written down than to imply it by "typically greater than corresponding
> > temp_crit"...
> >
> How about:
> Temperature emergency max value, for chips supporting more than
> two upper temperature limits. Must be equal or greater than
> corresponding temp_crit values.
> Unit: millidegree Celsius
> RW
Much better, thank you.
--