Re: [PATCH] regulator: Fix s5m8767_set_voltage_time_sel calculationvalue

From: Mark Brown
Date: Fri Mar 09 2012 - 07:33:32 EST


On Fri, Mar 09, 2012 at 04:28:10PM +0900, Sangbeom Kim wrote:
> In the s5m8767_set_voltage_time_sel function, divisor unit is wrong.
> ramp_delay is usec unit. So 1000 should be multiplied.

Applied, thanks.