[ 59/75] md/raid5: Fix a bug about judging if the operation is syncing or replacing
From: Greg KH
Date: Fri May 04 2012 - 17:07:49 EST
3.3-stable review patch. If anyone has any objections, please let me know.
------------------
From: majianpeng <majianpeng@xxxxxxxxx>
commit c6d2e084c7411f61f2b446d94989e5aaf9879b0f upstream.
When create a raid5 using assume-clean and echo check or repair to
sync_action.Then component disks did not operated IO but the raid
check/resync faster than normal.
Because the judgement in function analyse_stripe():
if (do_recovery ||
sh->sector >= conf->mddev->recovery_cp)
s->syncing = 1;
else
s->replacing = 1;
When check or repair,the recovery_cp == MaxSectore,so syncing equal zero
not one.
This bug was introduced by commit 9a3e1101b827
md/raid5: detect and handle replacements during recovery.
so this patch is suitable for 3.3-stable.
Signed-off-by: majianpeng <majianpeng@xxxxxxxxx>
Signed-off-by: NeilBrown <neilb@xxxxxxx>
Cc: Jes Sorensen <Jes.Sorensen@xxxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>
---
drivers/md/raid5.c | 4 +++-
1 file changed, 3 insertions(+), 1 deletion(-)
--- a/drivers/md/raid5.c
+++ b/drivers/md/raid5.c
@@ -3277,12 +3277,14 @@ static void analyse_stripe(struct stripe
/* If there is a failed device being replaced,
* we must be recovering.
* else if we are after recovery_cp, we must be syncing
+ * else if MD_RECOVERY_REQUESTED is set, we also are syncing.
* else we can only be replacing
* sync and recovery both need to read all devices, and so
* use the same flag.
*/
if (do_recovery ||
- sh->sector >= conf->mddev->recovery_cp)
+ sh->sector >= conf->mddev->recovery_cp ||
+ test_bit(MD_RECOVERY_REQUESTED, &(conf->mddev->recovery)))
s->syncing = 1;
else
s->replacing = 1;
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/