Re: [PATCH RFT 1/2] regulator: wm8350: Use wm8350_ldo_list_voltageinstead of open code to verify selected voltage
From: Mark Brown
Date: Sun Jun 17 2012 - 15:52:02 EST
On Tue, Jun 12, 2012 at 08:08:30PM +0800, Axel Lin wrote:
> Call wm8350_ldo_list_voltage() instead of open code to verify selected voltage
> falls within specified range.
> Use wm8350_ldo_list_voltage() here is less error prone.
Applied, thanks.