On Fri, 27 Jul 2012 14:45:18 -0700, you wrote:
On 07/27/2012 12:08 PM, Bill Davidsen wrote:Plus I disable the on-drive queuing (NCQ) during startup, right nowHave you set the io scheduler to deadline on all members of the array?I have not, thanks for the tip, I'll look into that now.
That's kind of "job one" on older kernels.
I don't have benchmarks to show the difference. This on a six by 1TB
drive RAID6 array I built over a year ago on Slackware64-13.37:
# cat /etc/rc.d/rc.local
...
# turn off NCQ on the RAID drives by adjusting queue depth to 1
n=1
echo "rc.local: Disable RAID drives' NCQ"
for d in a b c d e f
do
echo " set NCQ depth to $n on sd${d}"
echo $n> /sys/block/sd${d}/device/queue_depth
done
...
Maybe you could try that? See if it makes a difference. My drives
are Seagate.
Grant.