Re: [RFC][PATCH v3 1/3] runtime interpreted power sequences

From: Alex Courbot
Date: Tue Jul 31 2012 - 22:48:39 EST


On 07/31/2012 07:19 PM, Thierry Reding wrote:
* PGP Signed by an unknown key

On Tue, Jul 31, 2012 at 06:51:03PM +0900, Alex Courbot wrote:
On 07/30/2012 08:33 PM, Thierry Reding wrote:
+You will need an instance of power_seq_resources to keep track of the resources
+that are already allocated. On success, the function returns a devm allocated
+resolved sequence that is ready to be passed to power_seq_run(). In case of
+failure, and error code is returned.

I don't quite understand why the struct power_seq_resources is needed.
Can this not be stored within power_seq?

power_seq_resources serves two purposes:
1) When parsing sequences, it keeps track of the resources we have
already allocated to avoid getting the same resource twice
2) On cleanup, it cleans the resources that needs to be freed (i.e.
those that are not devm-handled).

2) can certainly be removed either by enforcing use of devm, or by
doing reference counting. 1) seems more difficult to avoid - we need
to keep track of the resources we already own between calls to
power_seq_build(). I'd certainly be glad to remove that structure
from public view and simplify the code if that is possible though.

I still don't see the problem. Managing the resources should be part of
the power_seq core and shouldn't be visible to users. Maybe what you are
worried about is that you may need the same resource both for a power-up
and a power-down sequence? I can see how that would require a global
list of resources.

Yes, that is precisely my concern. Sorry for not stating that more clearly.

However I still think it would be easier to encapsulate that completely.
Maybe another level of abstraction is required. You could for example
add another type to encapsulate several power sequences and that could
keep a list of used resources. I can't think of a good name, but maybe
the following DT snippet clarifies what I mean:

power-sequences {
#address-cells = <1>;
#size-cells = <0>;

sequence@0 {
name = "up";

#address-cells = <1>;
#size-cells = <0>;

step@0 {
...
};

...
};

sequence@1 {
name = "down";

#address-cells = <1>;
#size-cells = <0>;

step@0 {
...
};

...
};
};

If you add a name property like this, you could extend the API to
support running a named sequence:

power_seq_run(seq, "up");
...
power_seq_run(seq, "down);

Mmm, that's something to consider. Forcing power sequences to be grouped within a "power-sequences" node would also make parsing easier from the driver side since it would not have to explicitly parse every sequence. We could even imagine some tighter integration with the device subsystem to automatically run specifically-named sequences during suspend/resume. But maybe I'm thinking too much here.


Also, is there some way we can make the id property for GPIOs not
require the -gpio suffix? If the resource type is already GPIO, then it
seems redundant to add -gpio to the ID.

There is unfortunately an inconsistency between the way regulators
and GPIOs are gotten by name. regulator_get(id) will expect to find
a property named "id-supply", while gpio_request_one(id) expects a
property named exactly "id". To workaround this we could sprintf the
correct property name from a non-suffixed property name within the
driver, but I think this actually speaks more in favor of having
phandles directly into the sequences.

Yes, if it can be made to work by specifying the phandle directly that
is certainly better.

Let's do that then - as for the PWM issue I had, let's address that by clearly stating in the documentation that phandles referring to a same device *must* be identical.

+ if (!seq) return 0;

I don't think this is acceptable according to the coding style. Also,
perhaps returning -EINVAL would be more meaningful?

I neglected running checkpatch before submitting, apologies for
that. The return value seems correct to me, a NULL sequence has no
effect.

But seq == NULL should never happen anyway, right?

It could if you are parsing a NULL node. It seems safe to me to consider that a NULL sequence is an empty sequence, but if I go for your solution involving another data structure to encapsulate the sequence, then this might change.

Perhaps this should check for POWER_SEQ_STOP instead?

There is no resource for POWER_SEQ_STOP - therefore, a NULL resource
is used instead.

Still, you use POWER_SEQ_STOP as an explicit sentinel to mark the end of
a sequence, so intuitively I'd be looking for that as a stop condition.

That is for platform data - resolved sequences get their type from their resource, and a STOP sequence does not have a resource. But the STOP type will go away too since we will have a steps count in the platform data instead.

I would like to do that actually. The issue is that it did not work
go well with the legacy pwm_backlight behavior: a power sequence
needs to be constructed out of a PWM obtained through
pwm_request(int pwm_id, char *label) and this behavior cannot be
emulated using the new platform data interface (which only works
with pwm_get()). But if I remove this old behavior, then I could
make power_seq opaque. I don't think many drivers are using it. What
do you think?

I don't see how that is relevant here, since this power-sequencing code
is supposed to be generic and not tied to any specific implementation.
Can you explain further?

In any case you shouldn't be using pwm_request() in new code.

Power sequences only rely on pwm_get, and never call pwm_request since it is, as you stated, deprecated. However there are still boards that use the old pwm_id member of the pwm_backlight_platform_data. For these, we must call pwm_request from the pwm_backlight driver in order to resolve the PWM (see pwm_backlight_legacy_probe of the seconds patch). As the PWM is being resolved by the backlight driver, and not within the power sequences parser, the resolved data structure must be visible to pwm_backlight so it can construct it. There are two ways to solve this and keep the power sequences structure private:

1) Add a way to resolve a PWM by id using pwm_request in the power sequences (we probably should not do that)
2) Port the old platform pwm_request code to use pwm_add_table and pwm_get instead.

Do I get points if I do 2)? :)

Thanks,
Alex.

--