Possible disk failure

From: Steven Rostedt
Date: Tue Nov 13 2012 - 22:54:11 EST


Hi Jens,

Since you helped me out before, I'm going to ask for some more help ;-)

I just recently purchased a new workstation from HP, and after fighting
with getting grub2 working the way I want, I kicked off a ktest run to
create a true min config. It basically disables options from the .config
file until it finds a .config that that boots but will fail if you
disable any of the configs that are set.

Anyway, in the middle of this test, I started getting these nasty ata
errors again (like the ones I got with the failed HD that you helped me
out with on G+). But this is a brand new spanking machine (with a new
HD), but I could have gotten a lemon.

Anyway, the full dmesg is at:

http://rostedt.homelinux.com/private/bxtest-ata-fail-dmesg

And here's a smartctl dump:

[root@bxtest ~]# smartctl --all /dev/sda
smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.5.5-custom] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar Blue Serial ATA
Device Model: WDC WD5000AAKX-60U6AA0
Serial Number: WD-WCC2EF801545
LU WWN Device Id: 5 0014ee 25ccb70a0
Firmware Version: 18.01H18
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Tue Nov 13 17:48:40 2012 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 40) The self-test routine was interrupted
by the host with a hard or soft reset.
Total time to complete Offline
data collection: ( 7860) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 80) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 78
3 Spin_Up_Time 0x0027 143 142 021 Pre-fail Always - 3850
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 138
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x002f 100 253 051 Pre-fail Always - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 43
10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 136
184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0
187 Reported_Uncorrect 0x0032 022 022 000 Old_age Always - 78
188 Command_Timeout 0x0032 094 094 000 Old_age Always - 6
190 Airflow_Temperature_Cel 0x0022 074 067 040 Old_age Always - 26 (Min/Max 26/27)
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 123
193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 14
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 1
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Interrupted (host reset) 80% 1 -

SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

[root@bxtest ~]#


Any help would be appreciated. Is this HD a lemon (need to return it?)
or did something else go wrong that is fixable.

Thanks!

-- Steve

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/