Re: [PATCH RFC/RFT] regulator: core: Fix continuous_voltage_range casein regulator_can_change_voltage

From: Marek Szyprowski
Date: Thu Dec 13 2012 - 03:56:23 EST


Hello,

On 12/12/2012 2:22 AM, Axel Lin wrote:
Regulator drivers with continuous_voltage_range flag set allows not setting
n_voltages. Thus if continuous_voltage_range is set, check the constraint range
instead.

Signed-off-by: Axel Lin <axel.lin@xxxxxxxxxx>
---
drivers/regulator/core.c | 12 +++++++++---
1 file changed, 9 insertions(+), 3 deletions(-)

diff --git a/drivers/regulator/core.c b/drivers/regulator/core.c
index 0f65b24..d7448ad 100644
--- a/drivers/regulator/core.c
+++ b/drivers/regulator/core.c
@@ -1885,9 +1885,15 @@ int regulator_can_change_voltage(struct regulator *regulator)
struct regulator_dev *rdev = regulator->rdev;

if (rdev->constraints &&
- rdev->constraints->valid_ops_mask & REGULATOR_CHANGE_VOLTAGE &&
- (rdev->desc->n_voltages - rdev->desc->linear_min_sel) > 1)
- return 1;
+ (rdev->constraints->valid_ops_mask & REGULATOR_CHANGE_VOLTAGE)) {
+ if (rdev->desc->n_voltages - rdev->desc->linear_min_sel > 1)
+ return 1;
+
+ if (rdev->desc->continuous_voltage_range &&
+ rdev->constraints->min_uV && rdev->constraints->max_uV &&
+ rdev->constraints->min_uV != rdev->constraints->max_uV)
+ return 1;
+ }

return 0;
}


This change looks reasonable, I've missed the fact that there is a
support for regulators with continuous voltage range. This change also
shows that the n_voltages based workaround used earlier by mmc core was
indeed only a hack and regulator_can_change_voltage() approach is much
cleaner solution.

Best regards
--
Marek Szyprowski
Samsung Poland R&D Center

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/