Re: [4/7] i2c-designware: use dynamic adapter numbering on Lynxpoint
From: Mika Westerberg
Date: Tue Apr 09 2013 - 05:19:37 EST
On Tue, Apr 09, 2013 at 11:06:05AM +0200, Wolfram Sang wrote:
> On Thu, Mar 21, 2013 at 02:09:57AM -0000, Mika Westerberg wrote:
> > It is not good idea to mix static and dynamic I2C adapter numbering. In
> > this particular case on Lynxpoint we had graphics I2C adapter which took
> > the first numbers preventing the designware I2C driver from using the
> > adapter numbers it preferred.
> >
> > Fix this by switching to use dynamic adapter numbering on Intel Lynxpoint.
> >
> > Signed-off-by: Mika Westerberg <mika.westerberg@xxxxxxxxxxxxxxx>
>
> I am fearing regressions here if the bus numbering changes.
There are no users for this dynamic numbering yet since it was introduced
with the Lynxpoint support.
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html