Re: [5/9] thermal: exynos: Make the zone handling dependent on tripcount

From: Eduardo Valentin
Date: Fri Apr 12 2013 - 08:45:19 EST


On 12-04-2013 07:16, amit daniel kachhap wrote:
Hi Eduardo,

On Fri, Apr 12, 2013 at 2:18 AM, Eduardo Valentin
<eduardo.valentin@xxxxxx> wrote:
On 26-03-2013 07:33, Amit Daniel Kachhap wrote:

This code changes the zone handling to use the trip count passed
by the TMU driver. This also helps in adding more zone support.

Signed-off-by: Amit Daniel Kachhap <amit.daniel@xxxxxxxxxxx>

---
drivers/thermal/samsung/exynos_common.c | 56
+++++++++++++------------
drivers/thermal/samsung/exynos_common.h | 13 +++---
include/linux/platform_data/exynos_thermal.h | 7 ++-
3 files changed, 40 insertions(+), 36 deletions(-)

diff --git a/drivers/thermal/samsung/exynos_common.c
b/drivers/thermal/samsung/exynos_common.c
index 649d67c..0c0098d 100644
--- a/drivers/thermal/samsung/exynos_common.c
+++ b/drivers/thermal/samsung/exynos_common.c
@@ -84,17 +84,16 @@ static int exynos_set_mode(struct thermal_zone_device
*thermal,
static int exynos_get_trip_type(struct thermal_zone_device *thermal, int
trip,
enum thermal_trip_type *type)
{
- switch (GET_ZONE(trip)) {
- case MONITOR_ZONE:
- case WARN_ZONE:
- *type = THERMAL_TRIP_ACTIVE;
- break;
- case PANIC_ZONE:
- *type = THERMAL_TRIP_CRITICAL;
- break;
- default:
+ struct exynos_thermal_zone *th_zone = thermal->devdata;
+ int max_trip = th_zone->sensor_conf->trip_data.trip_count;
+
+ if (trip < 0 || trip >= max_trip)
return -EINVAL;
- }
+ else if (trip == (max_trip - 1))
+ *type = THERMAL_TRIP_CRITICAL;
+ else
+ *type = THERMAL_TRIP_ACTIVE;
+
return 0;
}

@@ -103,8 +102,9 @@ static int exynos_get_trip_temp(struct
thermal_zone_device *thermal, int trip,
unsigned long *temp)
{
struct exynos_thermal_zone *th_zone = thermal->devdata;
+ int max_trip = th_zone->sensor_conf->trip_data.trip_count;

- if (trip < GET_TRIP(MONITOR_ZONE) || trip > GET_TRIP(PANIC_ZONE))
+ if (trip < 0 || trip >= max_trip)
return -EINVAL;

*temp = th_zone->sensor_conf->trip_data.trip_val[trip];
@@ -118,10 +118,10 @@ static int exynos_get_trip_temp(struct
thermal_zone_device *thermal, int trip,
static int exynos_get_crit_temp(struct thermal_zone_device *thermal,
unsigned long *temp)
{
- int ret;
- /* Panic zone */
- ret = exynos_get_trip_temp(thermal, GET_TRIP(PANIC_ZONE), temp);
- return ret;
+ struct exynos_thermal_zone *th_zone = thermal->devdata;
+ int max_trip = th_zone->sensor_conf->trip_data.trip_count;
+ /* Get the temp of highest trip*/
+ return exynos_get_trip_temp(thermal, max_trip - 1, temp);
}

int exynos_get_frequency_level(unsigned int cpu, unsigned int freq)
@@ -157,7 +157,7 @@ static int exynos_bind(struct thermal_zone_device
*thermal,
tab_size = data->cooling_data.freq_clip_count;

if (tab_ptr == NULL || tab_size == 0)
- return -EINVAL;
+ return 0;

/* find the cooling device registered*/
for (i = 0; i < th_zone->cool_dev_size; i++)
@@ -206,7 +206,7 @@ static int exynos_unbind(struct thermal_zone_device
*thermal,
tab_size = data->cooling_data.freq_clip_count;

if (tab_size == 0)
- return -EINVAL;
+ return 0;

/* find the cooling device registered*/
for (i = 0; i < th_zone->cool_dev_size; i++)


The above two chunks are confusing. I dont understand how they are now
supposed to be valid settings.
Well it is made valid when there is no cooling table registered and
hence no cooling.

I suppose that is the case when you have sensors covering domains different of your CPU domain, where you cool off using cpufreq (table), right?

I suggest you adding a comment explaining why this is now valid..




@@ -366,19 +366,21 @@ int exynos_register_thermal(struct
thermal_sensor_conf *sensor_conf)
return -ENOMEM;

th_zone->sensor_conf = sensor_conf;
- cpumask_set_cpu(0, &mask_val);
- th_zone->cool_dev[0] = cpufreq_cooling_register(&mask_val);
- if (IS_ERR(th_zone->cool_dev[0])) {
- pr_err("Failed to register cpufreq cooling device\n");
- ret = -EINVAL;
- goto err_unregister;
+ if (sensor_conf->cooling_data.freq_clip_count > 0) {
+ cpumask_set_cpu(0, &mask_val);
+ th_zone->cool_dev[0] =
cpufreq_cooling_register(&mask_val);
+ if (IS_ERR(th_zone->cool_dev[0])) {
+ pr_err("Failed to register cpufreq cooling
device\n");
+ ret = -EINVAL;
+ goto err_unregister;
+ }
+ th_zone->cool_dev_size++;
}
- th_zone->cool_dev_size++;

th_zone->therm_dev =
thermal_zone_device_register(sensor_conf->name,
- EXYNOS_ZONE_COUNT, 0, th_zone, &exynos_dev_ops,
NULL, 0,
- sensor_conf->trip_data.trigger_falling ?
- 0 : IDLE_INTERVAL);
+ sensor_conf->trip_data.trip_count, 0, th_zone,
&exynos_dev_ops,
+ NULL, 0, sensor_conf->trip_data.trigger_falling ?
+ 0 : IDLE_INTERVAL);

if (IS_ERR(th_zone->therm_dev)) {
pr_err("Failed to register thermal zone device\n");
diff --git a/drivers/thermal/samsung/exynos_common.h
b/drivers/thermal/samsung/exynos_common.h
index b8d289e..453e09a 100644
--- a/drivers/thermal/samsung/exynos_common.h
+++ b/drivers/thermal/samsung/exynos_common.h
@@ -27,23 +27,22 @@
#define SENSOR_NAME_LEN 16
#define MAX_TRIP_COUNT 8
#define MAX_COOLING_DEVICE 4
-#define MAX_THRESHOLD_LEVS 4
+#define MAX_THRESHOLD_LEVS 5

#define ACTIVE_INTERVAL 500
#define IDLE_INTERVAL 10000
#define MCELSIUS 1000

/* CPU Zone information */
-#define PANIC_ZONE 4
-#define WARN_ZONE 3
-#define MONITOR_ZONE 2
-#define SAFE_ZONE 1
+#define PANIC_ZONE 5
+#define ALARM_ZONE 4
+#define WARN_ZONE 3
+#define MONITOR_ZONE 2
+#define SAFE_ZONE 1



Updating this does not seam to be part of the intent of this patch. You
probably want to send a separate patch for this.
yes right.


#define GET_ZONE(trip) (trip + 2)
#define GET_TRIP(zone) (zone - 2)

-#define EXYNOS_ZONE_COUNT 3
-
struct thermal_trip_point_conf {
int trip_val[MAX_TRIP_COUNT];
int trip_count;
diff --git a/include/linux/platform_data/exynos_thermal.h
b/include/linux/platform_data/exynos_thermal.h
index da7e627..893b758 100644
--- a/include/linux/platform_data/exynos_thermal.h
+++ b/include/linux/platform_data/exynos_thermal.h
@@ -23,6 +23,8 @@
#define _LINUX_EXYNOS_THERMAL_H
#include <linux/cpu_cooling.h>

+#define MAX_TRIP 5
+



Should MAX_TRIP/THRESHOLD_LEVEL/PANIC_ZONE be somewhat same
Yes they can be removed.


enum calibration_type {
TYPE_ONE_POINT_TRIMMING,
TYPE_TWO_POINT_TRIMMING,
@@ -100,11 +102,12 @@ struct freq_clip_table {
struct exynos_tmu_platform_data {
u8 threshold;
u8 threshold_falling;
- u8 trigger_levels[4];
+ u8 trigger_levels[MAX_TRIP];
bool trigger_level0_en;
bool trigger_level1_en;
bool trigger_level2_en;
bool trigger_level3_en;
+ bool trigger_level4_en;

u8 gain;
u8 reference_voltage;
@@ -113,7 +116,7 @@ struct exynos_tmu_platform_data {

enum calibration_type cal_type;
enum soc_type type;
- struct freq_clip_table freq_tab[4];
+ struct freq_clip_table freq_tab[MAX_TRIP];
unsigned int freq_tab_count;
};
#endif /* _LINUX_EXYNOS_THERMAL_H */





--