All regulators have ascendant voltage list in this driver.
Thus use regulator_map_voltage_ascend is more efficient than the default
regulator_map_voltage_iterate.
Signed-off-by: Axel Lin <axel.lin@xxxxxxxxxx>
---
drivers/regulator/lp3971.c | 2 ++
1 file changed, 2 insertions(+)
diff --git a/drivers/regulator/lp3971.c b/drivers/regulator/lp3971.c
index 9cb2c0f..d8af9e7 100644
--- a/drivers/regulator/lp3971.c
+++ b/drivers/regulator/lp3971.c
@@ -163,6 +163,7 @@ static int lp3971_ldo_set_voltage_sel(struct regulator_dev *dev,
static struct regulator_ops lp3971_ldo_ops = {
.list_voltage = regulator_list_voltage_table,
+ .map_voltage = regulator_map_voltage_ascend,
.is_enabled = lp3971_ldo_is_enabled,
.enable = lp3971_ldo_enable,
.disable = lp3971_ldo_disable,
@@ -236,6 +237,7 @@ static int lp3971_dcdc_set_voltage_sel(struct regulator_dev *dev,
static struct regulator_ops lp3971_dcdc_ops = {
.list_voltage = regulator_list_voltage_table,
+ .map_voltage = regulator_map_voltage_ascend,
.is_enabled = lp3971_dcdc_is_enabled,
.enable = lp3971_dcdc_enable,
.disable = lp3971_dcdc_disable,