Re: [RFC PATCH] regulator: palmas: enable all modes for SMPS10

From: Mark Brown
Date: Mon Jun 10 2013 - 06:04:04 EST


On Mon, Jun 10, 2013 at 03:20:06PM +0530, Kishon Vijay Abraham I wrote:
> On Tuesday 04 June 2013 03:35 PM, Mark Brown wrote:
> >On Tue, Jun 04, 2013 at 03:13:27PM +0530, Kishon Vijay Abraham I wrote:
> >>On Tuesday 04 June 2013 03:08 PM, Mark Brown wrote:

> >>>No. A boost regulator is still a voltage regulator, it just happens to
> >>>raise rather than lower the voltage but it's otherwise a normal
> >>>regulator. I'm not sure what you mean by "SWITCH" - from the name it'd
> >>>just be a bypass?

> SMPS10 has two outputs OUT2 and OUT1. In order to connect OUT2 to
> OUT1 we have to set "SWITCH_EN" bit in SMPS10_CTRL register.

Is that not just a normal enable?

Attachment: signature.asc
Description: Digital signature