Re: [PATCH] sound/sgtl5000: fix codec clock source transition toavoid clockless moment
From: Mark Brown
Date: Mon Aug 05 2013 - 12:08:15 EST
On Mon, Aug 05, 2013 at 07:36:02AM +0000, Oskar Schirmer wrote:
> Powering down PLL before switching to a mode that does not use it
> is a bad idea. It would cause the SGTL5000 be without internal
> clock supply, especially on the I2C interface, which would make
> subsequent access to it fail.
Applied, thanks. Please do use subject lines corresponding to the
subsystem.
Attachment:
signature.asc
Description: Digital signature