Re: [PATCHv3 05/16] hwmon: lm75: expose to thermal fw via DT nodes
From: Eduardo Valentin
Date: Sat Sep 21 2013 - 20:25:40 EST
On 21-09-2013 19:56, Guenter Roeck wrote:
> On 09/21/2013 04:30 PM, Eduardo Valentin wrote:
>> On 21-09-2013 14:06, Guenter Roeck wrote:
>>> On 09/18/2013 09:21 AM, Eduardo Valentin wrote:
>>>> This patch adds to lm75 temperature sensor the possibility
>>>> to expose itself as thermal zone device, registered on the
>>>> thermal framework.
>>>>
>>>> The thermal zone is built only if a device tree node
>>>> describing a thermal zone for this sensor is present
>>>> inside the lm75 DT node. Otherwise, the driver behavior
>>>> will be the same.
>>>>
>>>> Cc: Jean Delvare <khali@xxxxxxxxxxxx>
>>>> Cc: Guenter Roeck <linux@xxxxxxxxxxxx>
>>>> Cc: lm-sensors@xxxxxxxxxxxxxx
>>>> Cc: linux-kernel@xxxxxxxxxxxxxxx
>>>> Signed-off-by: Eduardo Valentin <eduardo.valentin@xxxxxx>
>>>
>>> Acked-by: Guenter Roeck <linux@xxxxxxxxxxxx>
>>>
>>
>> Cool! thanks again for taking the time to review this.
>>
>>> I assume this will be sent upstream through the thermal tree ?
>>
>> Yeah, that is the idea, at least for the core part. The hwmon changes I
>> believe goes via hwmon tree, right?
>>
>
> Not necessarily, as the hwmon code depends on the core code.
> In such cases it is quite common that both are sent through the same tree.
If this works for you I can queue these changes via the thermal tree.
>
> Guenter
>
>
>
--
You have got to be excited about what you are doing. (L. Lamport)