Re: [PATCH v2 1/2] regulator: as3722: Fix equation to calculate max_uVin regulator_lin_range macro

From: Laxman Dewangan
Date: Thu Oct 03 2013 - 08:07:40 EST


On Wednesday 02 October 2013 06:17 PM, Axel Lin wrote:
Fix off-by-one in the equation to calculate max_uV and also adjust the _min_uV
setting accordingly.

For LDOs:
The voltage select bits set the LDO output voltage 0.825V...3.3V, 25mV steps
....00h : LDO off
01h-24h : V_LDO4 = 0.8V + ldo4_vsel * 25mV
= 0.825V + (ldo4_vsel - 1h) * 25mV
25h-3Fh : do not use
40h-7Fh : V_LDO4 = 1.725V + (ldo4_vsel - 40h) * 25mV

For SD2345:
The voltage select bits set the DC/DC output voltage level and power the DC/DC
converter down.
....00h : DC/DC powered down
01h-40h : V_SD2 = 0.6V + sd2_vsel * 12.5mV
= 0.6125V + (sd2_vsel - 1h) * 12.5mV
41h-70h : V_SD2 = 1.4V + (sd2_vsel - 40h) * 25mV
= 1.425V + (sd2_vsel - 41h) * 25mV
71h-7Fh : V_SD2 = 2.6V + (sd2_vsel - 70h) * 50mV
= 2.65V + (sd2_vsel - 71h) * 50mV

Note, the third entry in as3722_sd2345_ranges is wrong in current code.
Fix it based on the datasheet.

Signed-off-by: Axel Lin <axel.lin@xxxxxxxxxx>
Acked-by: Laxman Dewangan <ldewangan@xxxxxxxxxx>
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html