Re: [PATCH] X.25: Fix address field length calculation

From: Kelleter, Günther
Date: Thu Oct 17 2013 - 08:09:52 EST



E.g. called address 7 digits and caller address 3 digits. Called DCE
answering without facilities
gives us this packet (hex):

37 12 34 56 71 23 00

then x25_parse_address_block() tries to pull 1+7+3 = 11 bytes from the
packet (with pskb_may_pull())
which only has 7 bytes.
When facilities are included the wrong calculated length has no effect
since the facilities make this packet long enough to make pskb_may_pull
with wrong number
of bytes succeed. later x25_addr_ntoa() correctly pulls 6 bytes for
addresses from the packet.


Am 17.10.2013 13:02, schrieb Andrew Hendry:
> Sorry for the previous html mail.
> This appears to be correct, what length addresses are you getting back
> in the call accept when this happens?
>
> On Wed, Oct 16, 2013 at 7:56 PM, David Laight <David.Laight@xxxxxxxxxx> wrote:
>>> On Tue, 2013-10-15 at 14:29 +0000, Kelleter, Günther wrote:
>>>> Addresses are BCD encoded, not ASCII. x25_addr_ntoa got it right.
>>> []
>>>> Wrong length calculation leads to rejection of CALL ACCEPT packets.
>>> []
>>>> diff --git a/net/x25/af_x25.c b/net/x25/af_x25.c
>>> []
>>>> @@ -98,7 +98,7 @@ int x25_parse_address_block(struct sk_buff *skb,
>>>> }
>>>> len = *skb->data;
>>>> - needed = 1 + (len >> 4) + (len & 0x0f);
>>>> + needed = 1 + ((len >> 4) + (len & 0x0f) + 1) / 2;
>>> This calculation looks odd.
>> Looks correct to me...
>> In X.25 the lengths (in digits) of the called and calling addresses
>> are encoded in the high and low nibbles of one byte and then
>> followed by both addresses with a digit in each nibble.
>> If the length of the first address is odd, the second one
>> isn't byte aligned.
>>
>> David
>>
>>
>>


--
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html