Re: [RFC 10/16] drm/nouveau/timer: skip calibration on GK20A
From: Stephen Warren
Date: Wed Feb 05 2014 - 15:27:53 EST
On 02/04/2014 01:39 AM, Alexandre Courbot wrote:
> On 02/04/2014 12:55 PM, Ben Skeggs wrote:
>> On Sat, Feb 1, 2014 at 1:16 PM, Alexandre Courbot
>> <acourbot@xxxxxxxxxx> wrote:
>>> GK20A's timer is directly attached to the system timer and cannot be
>>> calibrated. Skip the calibration phase on that chip since the
>>> corresponding registers do not exist.
>> Just a curiosity: What timer resolution does the HW initialise at?
>
> On T124 the timer input is the oscillator clock, which depending on the
> device can run between 12 and 48Mhz (IIUC).
On the one Tegra124 board we support upstream, the crystal is 12MHz. I
believe this is a typical/common value; almost all the Tegra boards we
support upstream run at this rate.
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/