[PATCH v3 1/3] net:phy:dp83640: Program pulsewidth2 values of perout triggers 0 and 1
From: Stefan SÃrensen
Date: Thu Feb 13 2014 - 09:35:58 EST
Periodic output triggers 0 and 1 of the dp83640 has a programmable
duty-cycle which is controlled by the Pulsewidth2 field of the trigger
data register. This field is not documented in the datasheet, but it
is described in the "PHYTER Software Development Guide" section
3.1.4.1. Failing to set the field can result in unstable/no trigger
output.
This patch add programming of the Pulsewidth2 field, setting it to the
same value as the Pulsewidth field for a 50% duty cycle.
Signed-off-by: Stefan SÃrensen <stefan.sorensen@xxxxxxxxxxxxxxx>
---
drivers/net/phy/dp83640.c | 5 +++++
1 file changed, 5 insertions(+)
diff --git a/drivers/net/phy/dp83640.c b/drivers/net/phy/dp83640.c
index 5ff221d..a370814 100644
--- a/drivers/net/phy/dp83640.c
+++ b/drivers/net/phy/dp83640.c
@@ -312,6 +312,11 @@ static void periodic_output(struct dp83640_clock *clock,
ext_write(0, phydev, PAGE4, PTP_TDR, sec >> 16); /* sec[31:16] */
ext_write(0, phydev, PAGE4, PTP_TDR, period & 0xffff); /* ns[15:0] */
ext_write(0, phydev, PAGE4, PTP_TDR, period >> 16); /* ns[31:16] */
+ /* Triggers 0 and 1 has programmable pulsewidth2 */
+ if (trigger == 0 || trigger == 1) {
+ ext_write(0, phydev, PAGE4, PTP_TDR, period & 0xffff);
+ ext_write(0, phydev, PAGE4, PTP_TDR, period >> 16);
+ }
/*enable trigger*/
val &= ~TRIG_LOAD;
--