Re: [PATCH V2] ONKEY: da9052: Use correct register bit for key status
From: Dmitry Torokhov
Date: Mon Feb 17 2014 - 14:29:40 EST
On Wed, Feb 12, 2014 at 02:11:34PM +0000, Anthony Olech wrote:
> The wrong register bit of the DA9052/3 PMIC registers was
> used to determine the status on the ONKEY.
>
> Also a failure in reading the status register will no longer
> result in the work queue being rescheduled as that would result
> in a (potentially) endless retry.
>
> Signed-off-by: Anthony Olech <anthony.olech.opensource@xxxxxxxxxxx>
> Acked-by: David Dajun Chen <david.chen@xxxxxxxxxxx>
Applied, thank you.
--
Dmitry
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/