Re: [PATCH v4 3/3] Documentation: of: Document graph bindings
From: Tomi Valkeinen
Date: Mon Mar 10 2014 - 02:54:26 EST
On 08/03/14 14:25, Grant Likely wrote:
> Sure. If endpoints are logical, then only create the ones actually
> hooked up. No problem there. But nor do I see any issue with having
> empty connections if the board author things it makes sense to have them
> in the dtsi.
I don't think they are usually logical, although they probably might be
in some cases.
As I see it, a "port" is a group of pins in a hardware component, and
two endpoints define a connection between two ports, which on the HW
level are the wires between the ports.
So a port with two endpoints is a group of pins, with wires that go from
the same pins to two different components.
Tomi