Re: man termios

From: Peter Hurley
Date: Fri Mar 21 2014 - 10:03:53 EST


On 03/21/2014 09:15 AM, Michael Kerrisk (man-pages) wrote:
On 03/21/2014 12:21 PM, Peter Hurley wrote:
On 03/21/2014 06:45 AM, Michael Kerrisk (man-pages) wrote:

Finally, if the 'count' parameter is less than MIN, read() may return before
MIN bytes have been received, if 'count' bytes have been received.

Yes. But it's not clear to me here: do you mean that something in the
man page (or in TLPI) needs fixing?

Well, what I mean here is that read() may also _not_ return until MIN bytes have
been received, even if 'count' bytes have been received.

Ahh -- I see what you mean. And, it looks like there is a point here where Linux
differs from POSIX and (at least) Solaris. See the current man-page text below,
in particular the MIN>0, TIME>0 case. I've also attached a simple test program
that I used, below.

In noncanonical mode input is available immediately (without the
user having to type a line-delimiter character), no input proâ
cessing is performed, and line editing is disabled. The settings
of MIN (c_cc[VMIN]) and TIME (c_cc[VTIME]) determine the circumâ
stances in which a read(2) completes; there are four distinct
cases:

MIN == 0; TIME == 0:
If data is available, read(2) returns immediately, with
the lesser of the number of bytes available, or the number
of bytes requested. If no data is available, read(2)
returns 0.

MIN > 0; TIME == 0:
read(2) blocks until MIN bytes are available, and returns
up to the number of bytes requested.

MIN == 0; TIME > 0:
TIME specifies the limit for a timer in tenths of a secâ
ond. The timer is started when read(2) is called.
read(2) returns either when at least one byte of data is
available, or when the timer expires. If the timer
expires without any input becoming available, read(2)
returns 0. If data is already available at the time of
the call to read() the call behaves as though the data was
received immediately after the call.

MIN > 0; TIME > 0:
TIME specifies the limit for a timer in tenths of a secâ
ond. Once an initial byte of input becomes available, the
timer is restarted after each further byte is received.
read(2) returns when any of the following conditions is
met:

* MIN bytes have been received.

* The interbyte timer expires.

* The number of bytes requested by read(2) has been
received. (POSIX does not specify this termination
condition, and on some other implementations read()
does not return in this case.)

Because the timer is started only after the initial byte
becomes available, at least one byte will be read. If
data is already available at the time of the call to
read() the call behaves as though the data was received
immediately after the call.

POSIX does not specify whether the setting of the O_NONBLOCK file
status flag takes precedence over the MIN and TIME settings. If
O_NONBLOCK is set, a read() in noncanonical mode may return immeâ
diately, regardless of the setting of MIN or TIME. Furthermore,
if no data is available, POSIX permits a read() in noncanonical
mode to return either 0, or -1 with errno set to EAGAIN.

All looks good.

Thanks again,
Peter Hurley

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/