Re: [PATCH net-next V6 0/2] cpumask,net: Affinity hint helper function
From: David Miller
Date: Sun Jun 01 2014 - 22:17:46 EST
From: Amir Vadai <amirv@xxxxxxxxxxxx>
Date: Sun, 25 May 2014 17:47:25 +0300
> This patchset will set affinity hint to influence IRQs to be allocated on the
> same NUMA node as the one where the card resides. As discussed in
> http://www.spinics.net/lists/netdev/msg271497.html
>
> If the number of IRQs allocated is greater than the number of local NUMA cores, all
> local cores will be used first, and the rest of the IRQs will be on a remote
> NUMA node.
> If no NUMA support - IRQ's and cores will be mapped 1:1
>
> Since the utility function to calculate the mapping could be useful in other mq
> drivers in the kernel, it was added to cpumask.[ch]
>
> This patchset was tested and applied on top of net-next since the first
> consumer is a network device (mlx4_en). Over commit 506724c: "tg3: Override
> clock, link aware and link idle mode during NVRAM dump"
>
> I couldn't find a maintainer for cpumask.c, so only added the kernel mailing
> list
Applied to net-next, thanks.
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html