[PATCH 27/94] iio: hid-sensor-magn-3d: Fix return values

From: Sam Asadi
Date: Tue Jul 15 2014 - 13:15:48 EST


From: Sachin Kamat <sachin.kamat@xxxxxxxxxxx>

IIO_CHAN_INFO_SAMP_FREQ and IIO_CHAN_INFO_HYSTERESIS cases ignored
the actual return values (which could be -EINVAL) and instead
returned IIO_VAL_INT_PLUS_MICRO always. Return the actual value
obtained from the functions. Both functions return IIO_VAL_INT_PLUS_MICRO
upon success.

Signed-off-by: Sachin Kamat <sachin.kamat@xxxxxxxxxxx>
Cc: Srinivas Pandruvada <srinivas.pandruvada@xxxxxxxxxxxxxxx>
Signed-off-by: Jonathan Cameron <jic23@xxxxxxxxxx>
Signed-off-by: sam-the-6 <asadi.samuel@xxxxxxxxx>
---
drivers/iio/magnetometer/hid-sensor-magn-3d.c | 7 ++-----
1 file changed, 2 insertions(+), 5 deletions(-)

diff --git a/drivers/iio/magnetometer/hid-sensor-magn-3d.c b/drivers/iio/magnetometer/hid-sensor-magn-3d.c
index 41cf29e..b2b0937 100644
--- a/drivers/iio/magnetometer/hid-sensor-magn-3d.c
+++ b/drivers/iio/magnetometer/hid-sensor-magn-3d.c
@@ -110,7 +110,6 @@ static int magn_3d_read_raw(struct iio_dev *indio_dev,
struct magn_3d_state *magn_state = iio_priv(indio_dev);
int report_id = -1;
u32 address;
- int ret;
int ret_type;
s32 poll_value;

@@ -153,14 +152,12 @@ static int magn_3d_read_raw(struct iio_dev *indio_dev,
ret_type = IIO_VAL_INT;
break;
case IIO_CHAN_INFO_SAMP_FREQ:
- ret = hid_sensor_read_samp_freq_value(
+ ret_type = hid_sensor_read_samp_freq_value(
&magn_state->common_attributes, val, val2);
- ret_type = IIO_VAL_INT_PLUS_MICRO;
break;
case IIO_CHAN_INFO_HYSTERESIS:
- ret = hid_sensor_read_raw_hyst_value(
+ ret_type = hid_sensor_read_raw_hyst_value(
&magn_state->common_attributes, val, val2);
- ret_type = IIO_VAL_INT_PLUS_MICRO;
break;
default:
ret_type = -EINVAL;
--
1.7.10.4

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/