On Fri, Oct 24, 2014 at 09:44:31AM -0700, Dmitry Torokhov wrote:Sorry for late reply.RK3288 reset circuit are first asynchronous reset and then sync revoked.
Hi Jinkun,
On Fri, Oct 24, 2014 at 12:29:19AM -0700, jinkun.hong wrote:
+static int rockchip_pd_power(struct rockchip_domain *pd, bool power_on)For my education, could you please tell me why we need to enable all
+{
+ int ret = 0;
+ struct rockchip_dev_entry *de;
+
+ mutex_lock(&pd->dev_lock);
+ /* no clk, set power domain will fail */
+ if (list_empty(&pd->dev_list)) {
+ pr_err("%s: no devices in %s power domain\n", __func__,
+ pd->base.name);
+ goto out;
+ }
+
+ list_for_each_entry(de, &pd->dev_list, node) {
+ pm_clk_resume(de->dev);
+ }
+
+ ret = rockchip_pmu_set_power_domain(pd, power_on);
+
+ list_for_each_entry(de, &pd->dev_list, node) {
+ pm_clk_suspend(de->dev);
+ }
+out:
+ mutex_unlock(&pd->dev_lock);
+ return ret;
+}
clocks of all devices in a power domain when we are talking to the PMU
and then turn them immediately off?
Can you tell me which one patch it. Thank you!Would not we want to enable clocks
in start()) callbacks, like Ulf mentioned?
Jinkun, any update on this question?
Thanks.