On 12/17/2014 05:27 PM, Lennart Sorensen wrote:
On Wed, Dec 17, 2014 at 09:22:25AM -0600, Nishanth Menon wrote:
A clock mux might do the job?
value 1, 2 , 3 will imply sysclk1 / 610
value of 0 implies fixed 32768
soemthing like
sys_clk32_crystal {
compatible = "fixed-clock";
clock-frequency = <32768>;
}
sys_clk32_pseudo {
compatible = "fixed-clock";
compatible = "fixed-factor-clock";
clocks = <&sys_clkin1>;
clock-mult = <1>;
clock-div = <610>;
}
sys_32k_ck: sys_32k_ck {
compatible = "ti,mux-clock";
clocks = <&sys_clk32_crystal>, <&sys_clk32_pseudo>, <&sys_clk32_pseudo>, <&sys_clk32_pseudo>;
};
I think... The only issue is that the BOOTSTRAP register is not around
the usual CM1,2 address region...
OK, I like where that idea is headed. That looks promising.
Yea clock mux can be used. However, we don't have support for DRA7
control module clocks in the DT yet. I have posted patches with support
towards this a couple of weeks back, but they need some revising.
Thus, we maybe need to apply the timer patches as is for now, and fix
the clock tree a bit later.