On 01/16/2015 06:48 AM, Archit Taneja wrote:
The NAND controller within EBI2 requires EBI2_CLK and EBI2_ALWAYS_ON_CLK clocks.
Create structs for these clocks so that they can be used by the NAND controller
driver. Add an entry for EBI2_AON_CLK in the gcc-ipq806x DT binding document.
Cc: Stephen Boyd <sboyd@xxxxxxxxxxxxxx>
Signed-off-by: Archit Taneja <architt@xxxxxxxxxxxxxx>
Looks ok. I couldn't find this used in the downstream sources though.
Can you point me to it? I'm mostly worried that this is a shared
resource that never should be turned off, so exposing it to drivers may
not be the right idea.
+static struct clk_branch ebi2_aon_clk = {
+ .hwcg_reg = 0x3b00,
+ .hwcg_bit = 6,
+ .halt_reg = 0x2fcc,
+ .halt_bit = 0,
+ .clkr = {
+ .enable_reg = 0x3b00,
+ .enable_mask = BIT(8),
+ .hw.init = &(struct clk_init_data){
+ .name = "ebi2_always_on_clk",
Can this be ebi2_aon_clk to match the macro?