Re: [PATCH V2] clk: mxs: Fix invalid 32-bit access to frac registers
From: Marek Vasut
Date: Wed Jan 21 2015 - 19:50:19 EST
On Wednesday, January 21, 2015 at 05:16:03 PM, Zhi Li wrote:
> On Sun, Dec 28, 2014 at 4:26 AM, Stefan Wahren <stefan.wahren@xxxxxxxx> wrote:
> > According to i.MX23 and i.MX28 reference manual the fractional
> > clock control registers must be addressed by byte instructions.
>
> I don't think mx23 and mx28 have such limitation. I will double check
> with IC team about this.
> RTL is generated from a xml file. All registers implement is unified.
> I don't think only clock control register have such limitation and
> other registers not.
Hi,
Section 10.8.24 in the MX28 datasheet (Fractional Clock Control Register 0)
states otherwise, but maybe the documentation is simply not matching the
silicon.
Here's a quote:
"
This register controls the 9-phase fractional clock dividers. The fractional
clock frequencies are a product of the values in these registers. NOTE: This
register can only be addressed by byte instructions. Addressing word or half-
word are not allowed.
"
I also recall seeing weird behavior when these registers were accessed by word
access in U-Boot, so I believe the datasheet is correct.
Best regards,
Marek Vasut
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/