Re: [PATCH 1/2] thermal: exynos: Fix wrong control of power down detection mode for Exynos7
From: Lukasz Majewski
Date: Wed Feb 25 2015 - 04:03:51 EST
Hi Abhilash,
> This patch fixes the wrong control of PD_DET_EN (power down detection
> mode) for Exynos7 because exynos7_tmu_control() always enables the
> power down detection mode regardless 'on' parameter.
>
> Cc: Zhang Rui <rui.zhang@xxxxxxxxx>
> Cc: Eduardo Valentin <edubezval@xxxxxxxxx>
> Signed-off-by: Chanwoo Choi <cw00.choi@xxxxxxxxxxx>
> ---
> drivers/thermal/samsung/exynos_tmu.c | 3 ++-
> 1 file changed, 2 insertions(+), 1 deletion(-)
>
> diff --git a/drivers/thermal/samsung/exynos_tmu.c
> b/drivers/thermal/samsung/exynos_tmu.c index 933cd80..a60f527 100644
> --- a/drivers/thermal/samsung/exynos_tmu.c
> +++ b/drivers/thermal/samsung/exynos_tmu.c
> @@ -682,6 +682,7 @@ static void exynos7_tmu_control(struct
> platform_device *pdev, bool on)
> if (on) {
> con |= (1 << EXYNOS_TMU_CORE_EN_SHIFT);
> + con |= (1 << EXYNOS7_PD_DET_EN_SHIFT);
> interrupt_en =
> (of_thermal_is_trip_valid(tz, 7)
> << EXYNOS7_TMU_INTEN_RISE7_SHIFT) |
> @@ -704,9 +705,9 @@ static void exynos7_tmu_control(struct
> platform_device *pdev, bool on) interrupt_en <<
> EXYNOS_TMU_INTEN_FALL0_SHIFT; } else {
> con &= ~(1 << EXYNOS_TMU_CORE_EN_SHIFT);
> + con &= ~(1 << EXYNOS7_PD_DET_EN_SHIFT);
> interrupt_en = 0; /* Disable all interrupts */
> }
> - con |= 1 << EXYNOS7_PD_DET_EN_SHIFT;
>
> writel(interrupt_en, data->base + EXYNOS7_TMU_REG_INTEN);
> writel(con, data->base + EXYNOS_TMU_REG_CONTROL);
Could you test this patch if it isn't introducing any regression on your
HW?
--
Best regards,
Lukasz Majewski
Samsung R&D Institute Poland (SRPOL) | Linux Platform Group
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/