[PATCH v6 22/22] arm: mach-pxa: Decrement the power supply's device reference counter

From: Krzysztof Kozlowski
Date: Tue Mar 10 2015 - 04:31:24 EST


Use power_supply_put() to decrement the power supply's device reference
counter.

Signed-off-by: Krzysztof Kozlowski <k.kozlowski@xxxxxxxxxxx>
Reviewed-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@xxxxxxxxxxx>
Reviewed-by: Sebastian Reichel <sre@xxxxxxxxxx>
Acked-by: Robert Jarzmik <robert.jarzmik@xxxxxxx>
Acked-by: Pavel Machek <pavel@xxxxxx>
---
arch/arm/mach-pxa/raumfeld.c | 4 +++-
1 file changed, 3 insertions(+), 1 deletion(-)

diff --git a/arch/arm/mach-pxa/raumfeld.c b/arch/arm/mach-pxa/raumfeld.c
index a762b23ac830..6dc4f025e674 100644
--- a/arch/arm/mach-pxa/raumfeld.c
+++ b/arch/arm/mach-pxa/raumfeld.c
@@ -758,8 +758,10 @@ static void raumfeld_power_signal_charged(void)
struct power_supply *psy =
power_supply_get_by_name(raumfeld_power_supplicants[0]);

- if (psy)
+ if (psy) {
power_supply_set_battery_charged(psy);
+ power_supply_put(psy);
+ }
}

static int raumfeld_power_resume(void)
--
1.9.1

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/