Re: [PATCH 01/13] thermal: Make temperatures consistently unsigned long
From: Sascha Hauer
Date: Fri Mar 27 2015 - 15:08:08 EST
On Fri, Mar 27, 2015 at 10:18:14AM +0000, Punit Agrawal wrote:
> Hi Sascha,
>
> Sascha Hauer <s.hauer@xxxxxxxxxxxxxx> writes:
>
> > The thermal framework uses int, long and unsigned long for temperatures
> > in millicelsius. The majority of functions uses unsigned long, so change
> > the remaining functions to use this type aswell.
> >
> > Signed-off-by: Sascha Hauer <s.hauer@xxxxxxxxxxxxxx>
>
> I'd suggest changing to long instead. It would allow the use of the
> thermal framework in environments where temperatures are below 0C -
> quite easily reached in many parts of the world.
I agree to use a signed type. I also found it not so nice that the thermal
core does not support negative temperatures. I only chose unsigned long
because the patch got smallest that way, but I already expected this
answer ;)
We could also use int instead of long. INT_MAX °mC is still enough for using
a computer on the surface of the sun (Not for the center though)